Technical Information
Detailed technical data for Day-Lite Architectural Wall Panel, including thermal performance, fire classification and materials.
Available Lengths
Standard Lengths (m) 1.2 - 8
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK and Ireland).
Dimensions, Weight & Thermal Performance
| Product Reference | Thickness(mm) | Weight (kg/m2) | U-value (W/m2 K) | Light Transmission (%) | Solar Heat Gain Coefficient |
|---|---|---|---|---|---|
| KS1000 DLAWP Opal* | 38 | 4.7 | 1.3 | 47 | 0.52 |
| KS1000 DLAWP Clear | 38 | 4.7 | 1.3 | 55 | 0.53 |
Notes: The U-value has been calculated using the method required by the appropriate National Building Regulations.
Light transmission, calculated values using measurements to BS EN 410.
* 99% diffusion.
Solar Heat Gain Coefficient (SHGC), according to BS EN 410, is the total solar energy that enters the interior of a building.
Please contact Kingspan Tech-eXchange for more information.
Reaction to Fire
The multiwall polycarbonate in Kingspan Day-Lite Architectural wall-lights have been tested to EN 13501-1, and achieves a reaction to fire classification of B-s1,d0 in both clear and opal.
For further guidance on the fire performance of our polycarbonate wall light systems please contact the Kingspan Tech-eXchange team.
Materials
External Weather Face
Multi-wall polycarbonate sheet 38mm thick x 1,000 mm wide with a flat external. The external face has a coextruded UV protection.
Spacers
Extruded mill-finished aluminium spacers are factory adhered to the Kingspan Day-Lite Architectural system. White polyethylene foam fillers are used to close off behind the ends of wall lights against supports
Warranty
The Kingspan Warranty covers the structural and thermal performance for a period of up to 25 years.
Downloads
Access product brochures, datasheets, and technical documentation to support specification and project planning.