Technical Information
Detailed technical data for QuadCore Topdek Roof Panels, including thermal performance, fire classification, air tightness, and acoustic properties.
Available Lengths
| Standard Lengths (m) | Longer Lengths (non-standard) (m) | Shorter Lengths (non-standard) (m) |
|---|---|---|
| 1.8 - 14.5 | 14.5 - 16 | Below 1.8 |
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK & Ireland).
Dimensions, Weight & Thermal Performance
| Core Thickness (mm) | Overall Thickness (mm) | U-value (W/m²K) | Weight (kg/m²) |
|---|---|---|---|
| 34 | 72 | 0.43 | 8.8 |
| 71 | 109 | 0.23 | 10.2 |
| 91 | 129 | 0.19 | 10.9 |
| 100 | 138 | 0.17 | 11.3 |
| 120 | 158 | 0.14 | 12.1 |
| 140 | 178 | 0.12 | 12.8 |
| 160 | 198 | 0.11 | 13.6 |
The QuadCore® insulation used in QuadCore® Topdek Roof Panels has a Thermal Conductivity (λ) of 0.018 W/m·K.
The Thermal Transmittance (U-Value) for the panels has been calculated using the method outlined in EN 14509, which takes in to account the panel longitudinal side joints.
Certification and Testing
Roof Applications
QuadCore Topdek Roof Panels are tested to:
Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1000TD when using Sikaplan SGK PVC membrane. This classification is valid for panel thicknesses from 34 – 160 mm and all roof pitches.
Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1000TD when using Armourplan TD PVC membrane. This classification is valid for panel thicknesses from 34 – 160 mm and all roof pitches
Fire Resistance
Fire resistance classifications are subject to panel thickness, method of assembly, membrane type and steel coating. Please contact Kingspan Tech-eXchange for project specific details.
Insurer Approvals
QuadCore Topdek Roof Panels are tested to:
FM 4471 approval standard for class 1 roof panels under the certified name QuadCore Topdek KS1000TD when using Sikaplan SGK PVC membrane. This classification is valid for panel thicknesses 71 – 160 mm.
FM 4471 approval standard for class 1 roof panels under the certified name QuadCore Topdek KS1000TDAR when using Armourplan TD PVC membrane. This classification is valid for panel thicknesses 71 – 160 mm.
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.

Air Leakage
An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels.
For information on detailing required to achieve lower air leakage rates, please contact Kingspan Tech-eXchange.
Acoustic
| Hz* | 125 | 250 | 500 | 1K | 2K | 4K |
|---|---|---|---|---|---|---|
| SRI | 18 | 18 | 17 | 23 | 30 | 40 |
QuadCore Topdek Roof Panel has a single figure weighted sound reduction Rw = 23dB. Results are based on panels of similar profile and core material.
*Frequency
Product Tolerance
| Cut to Length (< 3m) | ±5mm |
|---|---|
| Cut to Length (> 3m) | ±10mm |
| Cover Width | ±3mm |
| Thickness (Core ≤ 100mm) | ±2mm |
| Thickness (Core > 100mm) | ±2% |
| End Square | ±3mm |
Warranty
QuadCore Assured Panel Warranty
25 years thermal performance
25 years fire performanceÂ
25 years structural performance
25 years environmental performance
15 years membrane performance, which can be increased up to 25 years on application
NBS Specification
View QuadCore Topdek Roof Panel on NBS Source.
Downloads
Access product brochures, datasheets, and technical documentation to support specification and project planning.