Technical Information
Detailed technical information for the QuadCore Roofliner Roof Panel, including dimensions, thermal performance, certifications, fire classifications, acoustic properties and more.
Available Lengths
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK & Ireland).
| Standard Lengths (m) | Longer lengths (non-standard) (m) | Shorter Lengths (non-standard) (m) |
|---|---|---|
| 1.8 - 14.5 | 14.5 - 21.0 | Below 1.8 |
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK & Ireland).
Dimensions, Weight & Thermal Performance
| Core Thickness (mm) | U-Value (W/m²K) | Weight (kg/m²) |
|---|---|---|
| 50 | 0.38 | 11.1 |
| 60 | 0.31 | 11.5 |
| 80 | 0.23 | 12.3 |
| 100 | 0.18 | 13.0 |
| 125 | 0.15 | 14.0 |
| 150 | 0.12 | 14.9 |
| 175 | 0.10 | 15.9 |
| 200 | 0.09 | 16.8 |
| 220 | 0.08 | 17.6 |
Notes: These values are in accordance with BS EN 14509, calculated using Finite Element Analysis, and take into account any thermal bridging through the longitudinal joint. Shaded area denotes typical thicknesses for temperature controlled applications. The U-values have been calculated using an aged thermal conductivity value of 0.018 W/mK.
Certification and Testing
Reaction to Fire
QuadCore Roofliner Roof Panels are classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1: 2018 under the certified name KS1100RL when using the following internal liners: CLEANsafe 15, CLEANsafe 25, CLEANsafe 55, CLEANsafe 120 and AQUAsafe 55.
Please contact Kingspan Tech-eXchange for information relating to the external face.
Roof Applications
QuadCore Roofliner Roof Panels are tested to: Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1100RL for panel thicknesses 50 – 220 mm and roof pitch 0 – 10°.
Please contact Kingspan Tech-eXchange for information relating to the specific arrangement required for Broof(t4) classification.
Fire Resistance
Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating.
Please contact Kingspan Tech-eXchange for project specific details.
Air Leakage
An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels.
For information on detailing required to achieve lower air leakage rates please contact Kingspan Tech-eXchange.
Acoustic
| Frequency (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|
| SRI (dB) | 20 | 15 | 17 | 23 | 18 | 25 | 40 | 46 |
Sound Reduction Index (SRI)
QuadCore Roofliner Roof Panels have a single figure weighted sound reduction Rw = 24dB. Results are based on panels of similar profile and core material.
Product Tolerances
| Tolerance Type | Value |
|---|---|
| Cut to Length | ± 5mm |
| Cover Width | ± 2mm |
| Thickness (Core <100mm) | ± 2mm |
| Thickness (Core >100mm) | ± 2% |
| End Square | ± 3mm |
Warranty
QuadCore Assured Panel Warranty
25 years thermal performance
25 years fire performance
25 years structural performance
25 years environmental performance
Downloads