Commercial rooftops have the potential to offer an ideal platform for the installation of photovoltaics (PV), providing a source of renewable energy for the building occupier, and helping to meet important targets to cut carbon emissions. However, the prospect of more frequent and more severe weather events may raise concerns about how durable PV technology really is, and what impact the addition of a solar array could have on the structural integrity of roofs.

building with solar panels

Testing for asset protection

FM Approvals, part of worldwide insurance and risk management organisation FM, has developed a suite of rigorous tests to assess the performance of photovoltaics, as part of a complete roof system, in the face of fire, hail, wind uplift and gravity loading.

FM 4478 sets out the testing and certification requirements for rigid photovoltaic modules that are installed on a roof assembly that has itself achieved certification such as FM 4471.

A comprehensive assessment

The FM Approvals process does not simply assess products in isolation - it also includes an ongoing audit of the manufacturing facilities involved, as well as examination of the installation instructions and procedures, including potential field inspections. Only production run material is accepted for testing, and this is monitored through the auditing process.

Testing for wind uplift

On 24th January 2025, Storm Eowyn reached gusts of 100mph in Scotland, the most powerful windstorm for over a decade, posing a serious risk to life as well as to property. With the Met Office 2023/2024 storm season reporting no fewer than 12 named storms across the UK, the ability to withstand wind uplift is clearly a crucial factor when it comes to installing PV on commercial rooftops.

There are two test methods to assess wind uplift resistance under FM 4478. The first of these involves the minimum pressure the system must be able to withstand to achieve certification is 73 kgf/m² (kilogram force per square metre), or 0.7 kN/m² (kilonewton per square metre), going right up to a maximum of 293 kgf/m² (2.9 kN/m²). The system is tested until it fails, and must maintain 50% of the ultimate failure pressure for one minute without any visible cracking or creasing. The conditions for passing essentially require all fixings, components, adhesives and bonds to remain intact, and for the roof deck to maintain structural integrity throughout. The PV modules themselves must not puncture, fracture, crack, delaminate or separate from the frame.

The second test examines the pull-out resistance of the clamping system between the PV module and the roof deck, using a constant strain tensile machine to discover the maximum force that can be exerted before the clamp fails.

Testing for hail damage resistance

Interestingly, the most damaging hailstorms in the UK tend to be during the summer months, not the winter as you might expect. According to the Tornado and Storm Research Organisation (TORRO), there were 620 hailstorms between 1930 and 2009 that reached a damaging intensity. Although the incidence of truly destructive hailstorms is less frequent, the damage they do can be considerable.

FM 4478 uses a 1.5" or 38mm size ice ball at increasing speeds. As an indication of how severe this test is, this is the size of a hailstone that would be categorised as 'destructive' by TORRO, to the point of creating "wholesale destruction of glass, damage to tiled roofs, significant risk of injuries",  also "Bodywork of grounded aircraft dented, brick walls putted".

To meet the criteria for acceptance for hail damage resistance, the PV module must show no signs of "cracking or splitting, misaligned external surfaces, or rupture when examined under 10X magnification".

Protecting investments

Installing photovoltaics on a roof is a significant investment - one that could bring rich returns but also one that could leave a building roof vulnerable to damage if the installation is not robust. Using a standard such as FM 4478 provides specifiers, building owners and insurers with a clear benchmark of performance, and installers with a roadmap to best practice installation.

How can PowerPanel help?

One of the first systems globally to achieve FM 4478, PowerPanel combines the thermal efficiency of our industry leading QuadCore insulated panels with a highly effective monocrystalline photovoltaic technology in a single, precision-engineered component. This helps to reduce the risk of poor on site installation and ensures a high level of quality control for the entire system, which also carries the Kingspan PowerPanel Assured Warranty.