Application

The K-Roc® Roofliner Panel is ideal for low pitched roofs (≥1˚C) roofs with a considerable number of penetrations and for projects near the coast.

Dimensions, Thermal Performance & Weight
Thermal performance and weight data
Total R-Value (m²K/W)Total R-Value (m²K/W)
Panel Nominal Thickness (mm)Product R-Value (m²K/W) at 23°CProduct U-Value (W/m²K) at 23°CHeat Flow Out (Winter)Heat Flow In (Summer)Weight* (kg/m²)
1002.800.353.052.9023.00
1203.400.293.653.4525.50
1504.250.244.554.3029.00
1754.950.205.305.0031.75
2005.650.186.005.6534.50
  • The R-Values shown are Total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2: 2018.

  • K-Roc® Roofliner Panels are manufactured, tested and packaged in conformance with AS/NZS 4859.1: 2018.

  • Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code.

*Actual weight subject to vary ±10% due to manufacturing and raw material tolerances.

Available Lengths & Cover Widths
  • Standard lengths: 2.0 m - 12.0 m.

  • Export of Australia / sea freight to WA: 11.8 m.

  • Standard cover width: 1, 100 mm

Available Lengths
Core thickness (mm)Min. length (m)Max. length (m)
1002.010.0
1202.012.0
1502.012.0
1752.012.0
2002.012.0

Note: Additional costs and transport restrictions may apply for non-standard lengths.

Certification & Testing

Combustibility:

K-Roc® Roofliner Panel is a bonded laminated material. It achieves the following fire test results, as required by clause C2D10 (6)(g) of the National Construction Code (NCC). Therefore, it can be used wherever a non-combustible material is required by the NCC.

  • Mineral wool core is not deemed combustible when tested to AS 1530.1 1994 (R2016).

  • Panel steel skin (uncoated) is not deemed combustible when tested to AS 1530.1 1994 (R2016).

  • Test: Ignitability - Ignitability index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Flame Spread - Spread of flame index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Heat Release - Heat evolved index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Smoke Release - Smoke developed index: ≤3 as per AS/NZS: 1530.3: 1999

There are two factory-applied adhesive layers applied during the manufacture of the product. Each adhesive layer does not exceed 1 mm in thickness and the total thickness of the adhesive layers does not exceed 2 mm in thickness. K-Roc®Roofliner Panel meets the requirements of C2D15 ‘Fixing of Bonded Laminated Materials’ when located externally.

  • Test: NCC group number in accordance with AS 5637.1: 2015 using AS ISO 9705 2003 (R2016) is Group 1.

  • Smoke growth rate index (SMOGRARC) (m2/S2 x 1000) using AS ISO 9705 2003 (R2016) is <100.

Product Tolerances

Product tolerances in accordance with EN 14509: 2013.

Product Tolerances
Tolerance TypeTolerance
Length (≤ 3 m)± 5 mm
Length (> 3 m)± 10 mm
Width± 2 mm
Thickness (≤ 100 mm)± 2 mm
Thickness (> 100 mm)± 2 %
Squareness≤0.6% of width
Flatness* (L = 200 mm)0.6 mm
Flatness* (L = 400 mm)1.0 mm
Flatness* (L = 700 mm)1.5 mm
Bowing2 mm per metre length up to max. 20 mm

* Flatness shall be measured at least 100 mm from the edge of panel and 200 mm from the end of panel

Materials

External Weather Sheet:

  • Substrate to be G300S steel with AM100 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013.

Internal Liner:

  • Substrate to be G300S steel with Z275 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013.

Security. Built in.

K-Roc® panels engineered for high-security environments. Speak to Kingspan about our alternative material offering, proven across demanding security applications where durability, resilience and long-term performance are critical. Available on one or both sides of K-Roc® Roofliner Panels, in our standard paint coating offer. Contact Kingspan to discuss additional coating options and project-specific requirements.

Insulation core:

K-Roc® Roofliner Panels are manufactured with a 115 kg/m³ density mineral wool insulation core with a tolerance of ± 10%.

Coatings

External Weather Sheet:

  • Standard: Off White.

Internal Liner:

  • Standard: Coolroom White.

Other Internal Coating Options*

  • Kingspan AQUAsafe 25 and Kingspan AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments.

*Please contact Technical Services for further information regarding substrates and coatings. Internal coatings subject to availability and panel cover width.

Seals

Factory-applied side joint seals. External side joints have a factory-applied seal fitted into the groove to seal the joint between panels.

Downloads

Viewing 4 downloads
kingspan-k-roc-roofliner-roof-panel-data-sheet-en-au.pdf

K-Roc® Roofliner Panel Data Sheet

Data Sheets
Download
kingspan-k-roc-roofliner-panel-installation-guide-en-au.pdf

K-Roc® Roofliner Panel Install Guide

User/Installation Guides
Download
kingspan-data-centre-digital-brochure-en-au.pdf

Data Centre Solutions

Brochures
Download
kingspan-kip-product-lookbook-au.pdf

Product Lookbook

Brochures
Download
Video Showcase

Building Smarter with K-Roc®

OurK-Roc® mineral wool insulated panels are proudly manufactured in St Marys, Sydney, NSW.

Video Showcase

Data centre projects demand precision, speed, and consistency.

K-Roc® insulated panels are engineered to meet these needs, offering proven solutions that deliver fire protection, thermal efficiency, and design flexibility. These solutions have been created with Developers, Architects, Builders, and Installers in mind to help reduce risk, manage costs, and achieve sustainability requirements.

How can we help?

Our team can assist with product selection, technical guidance and specification advice for your next project.