K-Roc Firemaster Ceiling Panels are ideally suited for the construction of non-load bearing internal ceilings of food processing, data centres, microelectronics, and pharmaceuticals facilities, where protected zones or cleanrooms are often required. The K-Roc™ Firemaster Ceiling Panel is suitable for both walk-on (access and maintenance) and non-walk-on use.

Dimensions, Thermal Performance & Weight
Thermal Table
Total R-value (m²K/W)Total R-value (m²K/W)
Panel nominal thickness (mm)Product R-value (m²K/W) at 23°CProduct U-value (W/m²K) at 23°CHeat flow out (Winter)Heat flow in (Summer)Weight* (kg/m2)
1002.800.353.052.9023.00
1203.400.293.653.4525.50
1504.250.244.554.3029.00
1754.950.205.305.0031.75
2005.650.186.005.6534.50
  • The R-values shown are total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2: 2018.

  • K-Roc™ Firemaster Ceiling Panels are manufactured, tested, and packaged in conformance with AS/NZS 4859.1: 2018.

  • Declared product R-value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code.

*Actual weight subject to vary ±10% due to manufacturing and raw material tolerances.

Available Lengths & Cover Widths
  • Standard lengths: 2.0 m - 12.0 m.

  • Export of Australia / sea freight to WA: 11.8 m.

  • Standard cover width: 1, 100 mm

Available Lengths
Core thickness (mm)Min. length (m)Max. length (m)
1002.010.0
1202.012.0
1502.012.0
1752.012.0
2002.012.0

Note: Additional costs and transport restrictions may apply for non-standard lengths.

Certification & Testing

Combustibility:

K-Roc® Firemaster Ceiling Panel is a bonded laminated material. It achieves the following fire test results, as required by clause C2D10 (6)(g) of the National Construction Code (NCC). Therefore, it can be used wherever a non-combustible material is required by the NCC.

  • Mineral wool core is not deemed combustible when tested to AS 1530.1 1994 (R2016).

  • Panel steel skin (uncoated) is not deemed combustible when tested to AS 1530.1 1994 (R2016).

  • Test: Ignitability - Ignitability index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Flame Spread - Spread of flame index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Heat Release - Heat evolved index: 0 as per AS/NZS: 1530.3: 1999

  • Test: Smoke Release - Smoke developed index: ≤3 as per AS/NZS: 1530.3: 1999

There are two factory-applied adhesive layers applied during the manufacture of the product. Each adhesive layer does not exceed 1 mm in thickness and the total thickness of the adhesive layers does not exceed 2 mm in thickness

  • Test: NCC group number in accordance with AS 5637.1: 2015 using AS 5637.1: 2015 / ISO 9705 2003 (R2016) is Group 1.

  • Smoke growth rate index (SMOGRARC) (m2/S2 x 1000) using AS 5637.1: 2015 / ISO 9705 2003 (R2016) is <100.

Product Tolerances

* Flatness shall be measured at least 100 mm from the edge of panel and 200 mm from the end of panel.

Product tolerances for K-Roc™ Firemaster Ceiling Panels
Tolerance TypeTolerance
Length (≤ 3 m)± 5 mm
Length (> 3 m)± 10 mm
Width± 2 mm
Thickness (≤ 100 mm)± 2 mm
Thickness (> 100 mm)± 2 %
Squareness≤ 0.6% of width
Flatness* (L = 200 mm)0.6 mm
Flatness* (L = 400 mm)1.0 mm
Flatness* (L = 700 mm)1.5 mm
Bowing2 mm per metre length up to max. 20 mm

*Flatness shall be measured at least 100 mm from the edge of panel and 200 mm from the end of panel.

Materials

External Sheet:

  • Substrate to be G300S steel with AM100 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013.

Internal Liner:

  • Substrate to be G300S steel with Z275 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013.

Security. Built in.

K-Roc® panels engineered for high-security environments.

Speak to Kingspan about our alternative material offering, proven across demanding security applications where durability, resilience and long-term performance are critical.

Available on one or both sides of K-Roc® Firemaster Ceiling Panels, in our standard paint coating offer. Contact Kingspan to discuss additional coating options and project-specific requirements.

Insulation Core:

K-Roc® Firemaster Ceiling Panels are manufactured with a 115 kg/m³ density mineral wool insulation core with a tolerance of ± 10%

Coatings

External Sheet:

  • Standard: Off White. Other colours are available on request. Please contact your local area sales manager for further information.

Internal Liner:

  • Standard: Coolroom White

Other Internal Coating Options*

Kingspan AQUAsafe 25 and Kingspan AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments.

*Please contact Technical Services for further information regarding substrates and coatings. Internal coatings subject to availability and panel cover width.

Downloads

Viewing 3 downloads
kingspan-k-roc-firemaster-ceiling-panel-data-sheet-en-au.pdf

K-Roc® Firemaster Ceiling Panel Data Sheet

Data Sheets
Download
kingspan-data-centre-digital-brochure-en-au.pdf

Data Centre Solutions

Brochures
Download
kingspan-kip-product-lookbook-au.pdf

K-Roc™ Firemaster Ceiling Panel Lookbook

Brochures
Download