Technical Information
Comprehensive technical data for QuadCore Karrier Wall Panels, including dimensions, thermal and acoustic performance, certifications, materials, coatings, tolerances, and more.
Applications
QuadCore Karrier Wall Panels are an integral part of a lightweight, factory-engineered building system that comprises individual high-performance insulated panels that provide the support, thermal and weather protection for direct fix or ventilated cavity rainscreen facades.
Available Lengths
Standard lengths: 1.8 - 14.5 m
Longer lengths (non-standard): 14.5 –17.8 m
Shorter lengths (non- standard): Below 1.8 m
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK).
Dimensions, Weight & Thermal Performance
The QuadCore insulation used in QuadCore Karrier Wall Panels have a Thermal Conductivity (λ) of 0.018W/m.K
The above U-values are calculated based on the QuadCore Karrier Wall Panel component only.
QuadCore Karrier Wall Panels have a Thermal Transmittance (U-Value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland), Part L (Republic of Ireland) and Part F2 (Northern Ireland).
| Core thickness (mm) | 50 | 60 | 80 | 100 | 125 | 150 | 175 | 200 | 220 |
|---|---|---|---|---|---|---|---|---|---|
| U-value (W/m2K) | 0.38 | 0.31 | 0.23 | 0.18 | 0.15 | 0.12 | 0.10 | 0.09 | 0.08 |
| Weight (kg/m2) | 11.1 | 11.5 | 12.3 | 13.0 | 14.0 | 14.9 | 15.9 | 16.8 | 17.6 |
Certification and Testing
Reaction to Fire
QuadCore® Karrier Wall Panels are classified B-s1,d0 according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1: 2018, under the certified name QuadCore® Karrier when using the following internal liners:
CLEANsafe 15, CLEANsafe 25, CLEANsafe 55 and AQUAsafe 55.
This classification applies to the insulated panel component only. Please contact Kingspan Tech-eXchange for information relating to the external face.
BS 8414 Tested Systems
Dri-Design on QuadCore® Karrier has been tested to BS 8414-2 and has met the criteria of BR 135.
Test Report BS 8414-2: 2015 - P107922-1000
Classification Report BR 135: 2013 Annex B - P107922-1001
For further information on BS 8414 tested systems please contact Kingspan Tech-eXchange
Air Leakage
An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels.
For information on detailing required to achieve lower air leakage rates please contact Kingspan Tech-eXchange.
QuadCore Karrier Wall Panels achieve an air permeability classification of A4 according to CWCT / BS EN 12152 when sealed within the external female joint using factory applied weather seal.
For information on CWCT results for specific rainscreen finishes please contact Kingspan Tech-eXchange.
Water Tightness
QuadCore Karrier Wall Panels achieve a watertightness classification of R7 according to CWCT / BS EN 12154 when sealed within the external female joint using factory applied weather seal.
For information on CWCT results for specific rainscreen finishes please contact Kingspan Tech-eXchange.
Product Tolerance
Cut to Length (≤3m): ±5mm
Cut to Length (>3m): ±10mm
Cover Width: ±2mm
Thickness (Core ≤ 100mm): ±2mm
Thickness (Core > 100mm): ±2%
Flatness (per meter): ±1.5mm
End Square: ±3mm
Warranty
QuadCore® Assured Panel Warranty
25 years thermal performance
25 years fire performance
25 years structural performance
25 years environmental performance
*Please contact Kingspan Tech-eXchange or refer to the ‘QuadCore® Assured’ brochure for a list of accessories covered by Kingspan.
Site Installation Procedure
Site assembly instructions and construction details are available from Kingspan Tech-eXchange.
Downloads
We bring together products that are shaping the future of the built environment, from energy-efficient envelopes to intelligent building systems.