Skip to main content

Kingspan Insulated Panels

Welcome to Kingspan Insulated Panels

Technical Information

Comprehensive technical data for QuadCore Karrier Wall Panels, including dimensions, thermal and acoustic performance, certifications, materials, coatings, tolerances, and more.

Applications

QuadCore Karrier Wall Panels are an integral part of a lightweight, factory-engineered building system that comprises individual high-performance insulated panels that provide the support, thermal and weather protection for direct fix or ventilated cavity rainscreen facades.

Available Lengths

Standard lengths: 1.8 - 14.5 m

Longer lengths (non-standard): 14.5 –17.8 m

Shorter lengths (non- standard): Below 1.8 m

Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK).

Dimensions, Weight & Thermal Performance

The QuadCore insulation used in QuadCore Karrier Wall Panels have a Thermal Conductivity (λ) of 0.018W/m.K

The above U-values are calculated based on the QuadCore Karrier Wall Panel component only.

QuadCore Karrier Wall Panels have a Thermal Transmittance (U-Value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland), Part L (Republic of Ireland) and Part F2 (Northern Ireland).

Thermal Performance Data
Core thickness (mm)506080100125150175200220
U-value (W/m2K)0.380.310.230.180.150.120.100.090.08
Weight (kg/m2)11.111.512.313.014.014.915.916.817.6
Certification and Testing

Reaction to Fire

QuadCore® Karrier Wall Panels are classified B-s1,d0 according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1: 2018, under the certified name QuadCore® Karrier when using the following internal liners:

  • CLEANsafe 15, CLEANsafe 25, CLEANsafe 55 and AQUAsafe 55.

This classification applies to the insulated panel component only. Please contact Kingspan Tech-eXchange for information relating to the external face.

BS 8414 Tested Systems

Dri-Design on QuadCore® Karrier has been tested to BS 8414-2 and has met the criteria of BR 135.

Test Report BS 8414-2: 2015 - P107922-1000

Classification Report BR 135: 2013 Annex B - P107922-1001

For further information on BS 8414 tested systems please contact Kingspan Tech-eXchange

Air Leakage

An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels.

For information on detailing required to achieve lower air leakage rates please contact Kingspan Tech-eXchange.

QuadCore Karrier Wall Panels achieve an air permeability classification of A4 according to CWCT / BS EN 12152 when sealed within the external female joint using factory applied weather seal.

For information on CWCT results for specific rainscreen finishes please contact Kingspan Tech-eXchange.

Water Tightness

QuadCore Karrier Wall Panels achieve a watertightness classification of R7 according to CWCT / BS EN 12154 when sealed within the external female joint using factory applied weather seal.

For information on CWCT results for specific rainscreen finishes please contact Kingspan Tech-eXchange.

Product Tolerance
  • Cut to Length (≤3m): ±5mm

  • Cut to Length (>3m): ±10mm 

  • Cover Width: ±2mm 

  • Thickness (Core ≤ 100mm): ±2mm

  • Thickness (Core > 100mm): ±2%

  • Flatness (per meter): ±1.5mm

  • End Square: ±3mm

Warranty

QuadCore® Assured Panel Warranty

  • 25 years thermal performance

  • 25 years fire performance 

  • 25 years structural performance

  • 25 years environmental performance

*Please contact Kingspan Tech-eXchange or refer to the ‘QuadCore® Assured’ brochure for a list of accessories covered by Kingspan.

Site Installation Procedure

Site assembly instructions and construction details are available from Kingspan Tech-eXchange.

Downloads

We bring together products that are shaping the future of the built environment, from energy-efficient envelopes to intelligent building systems.

Viewing 4 downloads
kingspan-quadcore-karrier-panel-data-sheet-en-gb-ie.pdf

QuadCore Karrier Wall Panel Data Sheet

Data Sheet
Download
kingspan-quadcore-karrier-dop-en-gb-ie.pdf

QuadCore Karrier Wall Panel Declaration of Performance

'Declarations of Performance (DOPs)
Download
kingspan-quadcore-karrier-dop-en-gb-ie.pdf

Kingspan QuadCore Coldstore / Roofliner / Karrier Panel Reaction to fire EN13501-1-2018

Marketing Technical Assets
Download
kingspan-quadcore-karrier-panel-to-sfs-horizontal-install-guide-en-gb-ie.pdf

Kingspan QuadCore Karrier Panel to SFS Horizontal Install Guide

User/Installation Guides
Download
Tools & Resources

Technical Tools & Resources

Access a range of tools to support design, specification, and project delivery

Service slide 1
Calculations

Project-specific fastener requirements, U-value calculations, and condensation risk analysis.

Service slide 2
Fire Resistance

Fire performance data and guidance for insulated wall panel systems.

Service slide 4
Design Support

Book a virtual design consultation to discuss the specifics of your project

Service slide 4
BIM Collaboration

We offer a range of options to support BIM360

How can we help?

Get in touch today to discuss your needs and discover how we can support you.