Technical Information
Detailed technical data for QuadCore AWP Wall Panels, including thermal performance, fire classification, air tightness, and acoustic properties.
Available Lengths
| Length Type | Range |
|---|---|
| Standard lengths | 1.2 - 14.5 m |
| Longer lengths (non-standard) | 14.5 - 18.3 m |
| Shorter lengths (non-standard) | Below 1.2 m |
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK and Ireland).
Dimensions, Weight & Thermal Performance
| Core Thickness (mm) | 45 | 54 | 60 | 74 | 80 | 90 | 100 | 120 | 140 | 150 |
|---|---|---|---|---|---|---|---|---|---|---|
| U-value (W/m²K) | 0.46 | 0.35 | 0.32 | 0.25 | 0.23 | 0.20 | 0.19 | 0.15 | 0.13 | 0.12 |
| Weight (kg/m²) - Convex, Euro-Box, Flat-Stucco, Mini-Micro, Micro-Rib, Tramline & Wave | 8.7 | 9.1 | 9.3 | 9.8 | 10.1 | 10.5 | 10.8 | 11.6 | 12.4 | 12.7 |
| Weight (kg/m²) - Plank | 10.2 | 10.6 | 10.8 | 11.4 | 11.6 | 12.0 | 12.3 | 13.1 | 13.9 | 14.2 |
The QuadCore insulation used in AWP Wall Panel has a Thermal Conductivity (λ) of 0.018W/m.K. QuadCore AWP Wall Panel has a Thermal Transmittance (U-Value), calculated using the method required by the Building Regulations Part L2 (England & Wales), Building Standards Section 6 (Scotland), Part L (Republic of Ireland) and Part F2 (Northern Ireland).
Certification and Testing
Reaction to Fire
QuadCore AWP Wall Panel is classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) EN 13501-1:2018 under the certified name AWP Product Family when using the following internal liners: CLEANsafe 15, CLEANsafe 25, CLEANsafe 55, CLEANsafe120, AQUAsafe 55. Please contact Kingspan Tech-eXchange for information relating to the external face.
Fire Resistance
Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project-specific details.
Insurer Approvals
QuadCore® AWP Wall Panels are tested to:
LPS 1181 Part 1: Issue 1.2 Requirements and tests for builtup cladding and sandwich panel systems for use as the external envelope of buildings certified to:
– LPS 1181-1 Grade EXT-B under the certified name Kingspan QuadCore® KS600 – 1200 AWP, MR, FL, FL-S, EB, WV, MM, CX, PL, KS1000 TL for thicknesses 45 – 150 mm.
– LPS 1181-1 Grade EXT-A30 under the certified name Kingspan QuadCore® KS1000 AWP for thicknesses 80 – 150 mm.
FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials for thicknesses: – 45 – 150 mm and panel widths of 900 mm and 1000 mm. – 74 – 150 mm and panel width of 600 mm, 900 mm and 1000 mm.
FM 4881 approval standard for class 1 exterior wall systems for thicknesses: – 45 – 150 mm and panel widths of 900 mm and 1000 mm. – 74 – 150 mm and panel width of 600 mm, 900 mm and 1000 mm.
FM 4882 approval standard for class 1 interior wall and ceiling materials or systems for smoke sensitive occupancies for thicknesses: – 45 – 150 mm and panel widths of 900 mm and 1000 mm. – 74 – 150 mm and panel width of 600 mm, 900 mm and 1000 mm.
FM approvals are subject to the following certified names: For 1000 mm widths: KS1000AWP, KS1000MR, KS1000MM, KS1000EB, KS1000TL, KS1000PL, KS1000FL, KS1000FL-S, KS1000CX, KS1000WV. For 900 mm widths: KS900AWP, KS900MR, KS900MM, KS900EB, KS900PL, KS900FL, KS900FL-S, KS900CX, KS900WV. For 600 mm widths: KS600AWP, KS600MR, KS600MM, KS600EB, KS600PL, KS600FL, KS600FL-S, KS600CX, KS600WV.
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.

Air Leakage
An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels. For information on detailing required to achieve lower air leakage rates please contact Kingspan Tech-eXchange.
Acoustic
| Hz* | 63 | 125 | 250 | 500 | 1K | 2K | 4K | 8K |
|---|---|---|---|---|---|---|---|---|
| SRI | 20 | 15 | 17 | 23 | 18 | 25 | 40 | 46 |
QuadCore AWP Wall Panel has a single figure weighted sound reduction Rw = 24dB. Results are based on panels of similar profile and core material.
Product Tolerance
| Tolerance Type | Value |
|---|---|
| Cut to Length | ±5 mm |
| Cover Width | ±2 mm |
| Thickness (Core ≤ 100mm) | ±2 mm |
| Thickness (Core > 100mm) | ±2% |
| End Square | ±3 mm |
Warranty
QuadCore Assured Panel Warranty
25 years thermal performance 25 years fire performance 25 years structural performance 25 years environmental performance Up to 40 years coating performance
NBS Specification - standard