Technical Information
Detailed technical information for QuadCore Coldstore Panel, covering dimensions, thermal and acoustic performance, fire classification and warranty information. Full product information is available in the product data sheet.
Fire Performance Matrix
View our Fire Performance Matrix for wall and ceiling applications of QuadCore Coldstore Panel.
Available Lengths
Standard lengths: 1.8 - 14.5 m
Longer lengths (non-standard): 14.5 - 21.0 m
Shorter lengths (non-standard): Below 1.8m
Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK and Ireland).
Dimensions, Weight & Thermal Performance
| Core thickness (mm) | 50 | 60 | 80 | 100 | 125 | 150 | 175 | 200 | 220 |
|---|---|---|---|---|---|---|---|---|---|
| U-value (W/m².K) | 0.38 | 0.31 | 0.23 | 0.18 | 0.15 | 0.12 | 0.10 | 0.09 | 0.08 |
| Weight (kg/m²) | 10.1 | 10.5 | 11.2 | 12.0 | 12.9 | 13.9 | 14.8 | 15.8 | 16.5 |
Notes: These values are in accordance with BS EN 14509, calculated using Finite Element Analysis, and take into account any thermal bridging through the longitudinal joint. The U-values have been calculated using an aged thermal conductivity value of 0.018 W/m.K.
Certification and Testing
Reaction to Fire
QuadCore Coldstore Panels are classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501–1: 2018 under the certified name KS1100CS when using the following internal liners: CLEANsafe 15, CLEANsafe 25, CLEANsafe 55, CLEANsafe120, AQUAsafe 55. Please contact Kingspan Tech-eXchange for information relating to the external face.
Roof Applications
QuadCore Coldstore Panels are tested to:
Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1100CS QuadCore for panel thicknesses 50 – 220mm and roof pitch 0 - 10°.
Please contact Kingspan Tech-eXchange for information relating to the specific arrangement required for Broof(t4) classification.
Fire Resistance
Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details.
Insurer Approvals
QuadCore Coldstore Panels are tested to:
LPS 1181 Part 1: Issue 1.2 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings certified to:
-LPS 1181-1 Grade EXT-B under the certified name Kingspan IPN QuadCore KS600-1200 AB (roof/ceiling panel) for thicknesses 50 - 200 mm
LPS 1181 Part 2: Issue 2 Requirements and tests for sandwich panels and built-up systems for use as internal constructions in buildings certified to:
-LPS 1181-2 Grade INT-3 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall and ceiling panels) for thicknesses 80 - 200 mm
-LPS 1181-2 Grade INT-2 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 100 - 200 mm
-LPS 1181-2 Grade INT-2 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 125 - 200 mm
LPS 1208: Issue 2.2 LPCB test and performance requirements for walls, cavity barriers, floors and roofs certified to:
-FR30 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 100 - 220 mm
-FR30 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 100 - 220 mm
-FR60 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 175 - 220 mm
-FR60 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 175 - 220 mm
Please contact Kingspan Tech-eXchange for information relating to the specific arrangement required for LPS 1208 classification.
FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials under the certified name KS1100CS and KS1200CS for thicknesses 50 – 220mm
FM 4881 approval standard for class 1 exterior wall systems under the certified name KS1100CS and KS1200CS for thicknesses 50 – 220mm
FM 4882 approval standard for class 1 interior wall and ceiling materials or systems for smoke sensitive occupancies under the certified name KS1100CS and KS1200CS for thicknesses 50 – 220mm
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.

Certification and Testing LEC
Reaction to Fire
QuadCore Coldstore LEC Panels are classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1:2018 under the certified name KS1100 CS when using the following internal liners: CLEANsafe 15, CLEANsafe 25 and CLEANsafe 120.
Please contact Kingspan Tech-eXchange for information relating to the external face.
Roof Applications
QuadCore Coldstore LEC Panels are tested to: Broof(t4) to BS EN 13501-5: 20™ under the certified name KS1100 CS QuadCore for panel thicknesses 50 – 220mm and roof pitch 0 – 10°.
Please contact Kingspan Tech-eXchange for information relating to the specific arrangement required for Broof(t4) classification.
Fire Resistance
Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details.
Insurer Approvals
QuadCore Coldstore LEC Panels are tested to:
LPS 1181 Part 1: Issue 1.2 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings certified to: LPS 1181-1 Grade EXT-B under the certified name Kingspan IPN QuadCore KS600-1200 AB (roof/ceiling panel) for thicknesses 50 – 200mm.
LPS 1181 Part 2: Issue 2 Requirements and tests for sandwich panels and built-up systems for use as internal constructions in buildings certified to: – LPS 1181-2 Grade INT-3 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall and ceiling panels) for thicknesses 80 – 200mm
LPS 1181-2 Grade INT-2 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 100 – 200mm
LPS 1181-2 Grade INT-2 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 125 – 200mm.
LPS 1208: Issue 2.2 LPCB test and performance requirements for walls, cavity barriers, floors and roofs certified to:
– FR30 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 100 – 220mm.
– FR30 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 100 – 220mm
– FR60 under the certified name Kingspan IPN QuadCore KS600-1200 CS (wall panel) for thicknesses 175 – 220mm
– FR60 under the certified name Kingspan IPN QuadCore KS600-1200 CS (ceiling panel) for thicknesses 175 – 220mm
Please contact Kingspan Tech-eXchange for information relating to the specific arrangement required for LPS 1208 classification.
FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials under the certified name KS1100 CS and KS1200 CS for thicknesses 50 – 220mm.
FM 4881 approval standard for class 1 exterior wall systems under the certified name KS1100 CS and KS1200 CS for thicknesses 50 – 220mm.
FM 4882 approval standard for class 1 interior wall and ceiling materials or systems for smoke sensitive occupancies under the certified name KS1100 CS and KS1200 CS for thicknesses 50 – 220mm.
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.

Acoustic
| Hz* | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k |
|---|---|---|---|---|---|---|---|---|
| SRI | 15 | 16 | 21 | 24 | 17 | 44 | 46 | 51 |
Sound Reduction Index (SRI)
* Frequency
QuadCore Coldstore Panels have a single figure weighted sound reduction Rw(C;Ctr) = 26 (-4;-7) dB, rating according to BS EN ISO 717-1:2013. Results are based on QuadCore Coldstore 80mm thick panel, measurement of Sound Reduction Index to BS EN ISO 10140-2: 2010.
Heat Transmission
| Panel thickness (mm) | 50 | 60 | 80 | 100 | 125 | 150 | 175 | 200 | 220 |
|---|---|---|---|---|---|---|---|---|---|
| U-value (W/m2K) | 0.38 | 0.31 | 0.23 | 0.18 | 0.15 | 0.12 | 0.10 | 0.09 | 0.08 |
| Temperature difference (°C) | |||||||||
| 10 | 3.60 | 3.00 | 2.25 | 1.80 | 1.44 | 1.20 | 1.03 | 0.90 | 0.82 |
| 15 | 5.40 | 4.50 | 3.38 | 2.70 | 2.16 | 1.80 | 1.54 | 1.35 | 1.23 |
| 20 | 7.20 | 6.00 | 4.50 | 3.60 | 2.88 | 2.40 | 2.06 | 1.80 | 1.64 |
| 25 | 9.00 | 7.50 | 5.63 | 4.50 | 3.60 | 3.00 | 2.57 | 2.25 | 2.05 |
| 30 | 10.80 | 9.00 | 6.75 | 5.40 | 4.32 | 3.60 | 3.09 | 2.70 | 2.45 |
| 35 | 12.60 | 10.50 | 7.88 | 6.30 | 5.04 | 4.20 | 3.60 | 3.15 | 2.86 |
| 40 | 14.40 | 12.00 | 9.00 | 7.20 | 5.76 | 4.80 | 4.11 | 3.60 | 3.27 |
| 45 | 16.20 | 13.50 | 10.13 | 8.10 | 6.48 | 5.40 | 4.63 | 4.05 | 3.68 |
| 50 | 18.00 | 15.00 | 11.25 | 9.00 | 7.20 | 6.00 | 5.14 | 4.50 | 4.09 |
| 55 | 19.80 | 16.50 | 12.38 | 9.90 | 7.92 | 6.60 | 5.66 | 4.95 | 4.50 |
| 60 | 21.60 | 18.00 | 13.50 | 10.0 | 8.64 | 7.20 | 6.17 | 5.40 | 4.91 |
| 65 | 23.40 | 19.50 | 14.63 | 11.70 | 9.36 | 7.80 | 6.69 | 5.85 | 5.32 |
| 70 | 25.20 | 21.00 | 15.75 | 12.60 | 10.08 | 8.40 | 7.20 | 6.30 | 5.73 |
| 75 | 27.00 | 22.50 | 16.88 | 13.50 | 10.80 | 9.00 | 7.71 | 6.75 | 6.14 |
| 80 | 28.80 | 24.00 | 18.00 | 14.40 | 11.52 | 9.60 | 8.23 | 7.20 | 6.55 |
Thermal Conductivity (λ) 0.018 W/m.K
Notes: The heat gain by conduction should be limited to 10W/m2, for enhanced energy performance, the heat gain by conduction should be limited to 8W/m2 (Guidelines for the Design, Specification, Construction, Maintenance and Fire Management of Insulated Envelopes for Temperature Controlled Environments).
Product Tolerance
Cut to Length (≤3m): ±5mm
Cut to Length (>3m): ±10mm
Cover Width: ±2mm
Thickness (Core ≤ 100mm): ±2mm
Thickness (Core > 100mm): ±2%
Flatness (per meter): ±1.5mm
End Square: ±3mm
Warranty
QuadCore Assured Panel Warranty
25 years thermal performance
25 years fire performance
25 years structural performance
25 years environmental performance
Up to 40 years coating performance
NBS Specification
Environmental Product Declaration (EPD)
View the EPD for QuadCore Coldstore Panel.
View the EPD for QuadCore Coldstore LEC Panel
Downloads
Access product brochures, datasheets, and technical documentation to support specification and project planning.