Skip to main content

Kingspan Insulated Panels

Welcome to Kingspan Insulated Panels

How can we deal with existing high energy use buildings?

DATE PUBLISHED: 12 April 2024 LAST UPDATED: 19 February 2026

In the UK, 9 out of 10 buildings will need an upgrade by 2030 to stay on track with the current targets. One industry that needs rapid change yet seems one of the most difficult to do so, is the manufacturing industry. Factories in the UK are responsible for tens of millions of metric tons of carbon dioxide emissions each year. To improve this, and work towards a net zero future, innovation is crucial to the success of reducing carbon emissions and creating a more sustainable future for generations to come.

Case Study - Kingspan Group, Kingscourt Ireland

Our flagship manufacturing facility, Kingscourt, can be used to highlight the many options that factories have when it comes to cutting carbon. Prior to 2022, Kingscourt’s roof was in a poor condition. The building backdates to 1974 and the first Kingspan manufactured panel was created here in 1980. At this point, any asbestos sections had been removed from the roof and the new roof was constructed using 40mm of our PIR panels that were produced in house. Whilst PIR offers a functional insulant and great thermal efficiency when compared to single skin asbestos, this was still outdated compared to modern standards. Our intention was to also replace the rooflights which had become aged and had yellowed over time, limiting the amount of natural light let into the building.

The previous design still had the environment in mind and allowed for the building to have a lower carbon dependency. But, with recent technologies, we were now able to completely rethink the way in which our building ran, and with 30,000 metres of panel manufactured there each week, changes needed to be made quickly and efficiently. 

Kingscourt Ireland Roof Refurb
Out with the old, in with the new

The new roof was designed with our Planet Passionate programme in mind. Planet Passionate ensures that any project we undertake will:

  • Reduce energy usage.

  • Move us closer to a clean energy future.

  • Enable a more circular built environment.

To achieve this, we began by disposing of the original panels in an ethical manner. No part of the original roof was sent to landfill, everything was either reused or recycled, reducing the project’s carbon footprint massively.

For the new roof, we used software to ensure that every decision made was informed and the design was optimised wherever possible. Wind Load Analysis was used to analyse the effect wind would have on the structure. PV System software was used to discover the PV solar generation capacity of the system, as well as sizing and data analysis. Kingspan Daylight analysis software was also used to show the effect of upgrading to DTLR skylights. Using this software meant creating the perfect roof for the building’s needs but also protecting the environment for years to come. It also meant limited waste and a larger use of recycled products.

The key requirements for the roof were that it must offer better insulation for the building, reduce the need for fossil fuels to power the building and allow more natural light to the workspace down below, both reducing energy demand and having a positive effect on staff working in the building. To do this, we needed to choose the correct materials and structure.

By choosing to source all materials in-house, we could further reduce the carbon impact of this project and limit costs considerably.

The installation of over 10,000 m² of our roof panels and solar panels allowed a significant upgrade that improved the building's overall thermal performance and led to it having the capacity to generate 528,000 kWh per year (29.6% of the facility’s electrical power needs). This, alongside the addition of upgraded rooflights, vastly increased the levels of daylight on the factory floor, not only reducing the light energy consumption, but also enhancing our employee’s wellbeing.

QuadCore insulation has a declared thermal conductivity of 0.018 W/m.K compared to 0.023 W/m.K of the previously used PIR. QuadCore panels therefore offer a much more effective insulation to achieve improved U-values with minimal thickness, helping to reduce heating energy demand and ensuring a lesser reliance on fossil fuels.

Why not?

When making profound changes to a workspace, it is important that we look at the overall benefits that will come in time. Using renewables in the refurbishment of a factory may have a greater initial spend than if the roof were to simply be upgraded, however, a return on your investment is not far from reach.

The installation of Kingscourt’s new roof (which took a short period of 3 weeks), held a significant upfront investment, but from using high performing products that will ensure reduced heat loss, together with renewable energy generation, the calculated payback from energy saved through lighting, heating and electricity generation is 12 years.

As well as this, there were other benefits for our stakeholders:

  • With the new roof, Kingscourt can now generate up to 29.6% of the factory’s electrical power needs per year. This takes a substantial weight from our reliance on the local grid, and helps to provide greater levels of energy security for the local community.

  • Improved higher LUX levels and enhanced daylight quality have been shown to support employee’s health and wellbeing.

Action is needed to achieve the 2050 net zero targets, but there are a variety of solutions to support this that offer multiple benefits in terms of cutting carbon, reducing energy costs, and providing a healthier workspace. So why wait?

Find out more about our roofing solutions.

Discover More

Why Aesthetics Matter in Building Refurbishments

Why Aesthetics Matter in Building Refurbishments

We explore 5 reasons why aesthetics matter in building refurbishments
Roof Replacement Vs Roof Repair: A Guide for your Industrial Roof

Roof Replacement Vs Roof Repair: A Guide for your Industrial Roof

Your roof protects people and assets from the elements, and over time, wear and tear are inevitable
Signs the Roof Needs Replacing on your Commercial Building

Signs the Roof Needs Replacing on your Commercial Building

We explore key signs that indicate your roof may need some attention
5 Advantages Of A Timely Roof Replacement For Your Commercial Building

5 Advantages Of A Timely Roof Replacement For Your Commercial Building

In this article, we explore five key advantages for replacing your commercial building's roof
Storage World

Storage World

QuadCore AWP was used for a bold refurbishment of Manchester’s leading self-storage facility

How can we help?