Dimensions, Thermal Performance & Weight
Dimensions, thermal performance, and weight
Total R-value (m²K/W)Total R-value (m²K/W)
Nominal Thickness (mm)Product R-value (m²K/W) at 23°CProduct U-value (m²K/W) at 23°CHeat Flow Out (Winter)Heat Flow In (Summer)Weight* (kg/m²)
1504.250.244.554.2528.00
1754.950.205.304.9531.00
2005.650.186.005.6533.75
  • The R-Values shown are Total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2: 2018.

  • K-Roc® Evolution Ultima Plus Wall Panels are manufactured, tested, and packaged in conformance with AS/NZS 4859.1: 2018.

  • Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code.

* Actual weight subject to vary ± 10% due to manufacturing and raw material tolerances.

Available Lengths & Cover Widths
  • Standard lengths: 2.0 m - 12.0 m.

  • Export of Australia / sea freight to WA: 11.8 m.

  • Standard cover width: 1,000 mm

Available Lengths
Core thickness (mm)Min. length (m)Max. length (m)
1502.012.0
1752.012.0
2002.012.0

Note: Additional costs and transport restrictions may apply for non-standard lengths.

Certification & Testing

Combustibility:

K-Roc® Evolution Ultima Plus Wall Panel is a bonded laminated material. It achieves the following fire test results, as required by clause C2D10 (6)(g) of the National Construction Code (NCC). Therefore, it can be used wherever a non-combustible material is required by the NCC.

Component materials are tested to AS 1530.1:1994 (R2016):

  • Mineral wool core is not deemed combustible

  • Panel steel skin (uncoated) is not deemed combustible

Panel assembly is tested to AS/NZS 1530.3:1999:

  • Ignitability index: 0

  • Spread of Flame index: 0

  • Heat Evolved Index: 0

  • Smoke Developed Index: 3

There are two factory-applied adhesive layers applied during the manufacture of the product. Each adhesive layer does not exceed 1 mm in thickness, and the total thickness of the adhesive layers does not exceed 2 mm in thickness. K-Roc® Evolution Ultima Plus Wall Panel meets the requirements of C2D15 ‘Fixing of Bonded Laminated Materials’ when located externally.

Group Number:

When assessed in accordance with AS 5637.1:2015 via testing to AS ISO 9705:2003 (R2016) K-Roc Evolution Ultima Plus Wall Panel achieves the following:

  • Group Number: 1

  • Smoke growth rate index (SMOGRARC) (m2/S2 x 1000): <100.

Fire Resistance:

K-Roc® Evolution Ultima Plus Wall Panel is tested in accordance with AS 1530.4 2014. Fire-resistance Levels (FRL) are subject to certain details including panel thickness, width, orientation, distance between supports and method of assembly.

Please contact Technical Services for the specific information on the fire-resistance levels available and the installation detail required

K-Roc Evolution Ultima Fire Table
Panel Thickness (mm)Panel OrientationStitching RequiredMax. FRL Distance Between SupportsFRLDirection of fire exposure
175, 200VerticalNot required3.0 m-/240/180Outside to inside
175, 200VerticalNot required7.5 m-/180/180Outside to inside
175, 200VerticalNot required7.5 m-/120/120Either direction
150VerticalNot required3.0 m-/180/180Outside to inside
150VerticalNot required7.5 m-/120/120Outside to inside
150VerticalNot required3.0 m-/120/120Either direction
150, 175, 200HorizontalNot required3.0 m-/240/240Outside to inside
150, 175, 200HorizontalNot required7.5 m-/180/180Outside to inside
150, 175, 200HorizontalNot required7.5 m-/120/120Either direction

Notes: Tables must be read in conjunction with relevant fire resistance report. Maximum FRL distance between supports are confirming the maximum from a fire resistance perspective, additional loads anticipated from wind loads or other may result in reductions to maximum allowable distance between supports. Structure has not been included in the tables

Product Tolerances

In accordance with EN 14509: 2013.

Product tolerances
Length (≤ 3 m)± 5 mm
Length (> 3 m)± 10 mm
Width± 2 mm
Thickness (≤ 100 mm)± 2 mm
Thickness (> 100 mm)± 2 %
Squareness≤ 0.6% of width
Flatness* (L = 200 mm)0.6 mm
Flatness* (L = 400 mm)1.0 mm
Flatness* (L = 700 mm)1.5 mm
Bowing2 mm per metre length up to max. 20 mm

* Flatness shall be measured at least 100 mm from the edge of panel and 200 mm from the end of panel.

Materials

External Weather Sheet:

  • Substrate to be G300S steel with AM100 or AM150 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013

Internal Liner:

  • Substrate to be G300S steel with AM100 metallic coating in accordance with AS 1397: 2021.

  • Paint coating in accordance with AS / NZS 2728: 2013.

Security. Built in.

K-Roc® panels engineered for high-security environments.

Speak to Kingspan about our alternative material offering, proven across demanding security applications where durability, resilience and long-term performance are critical.

Available as an internal liner for K-Roc® Evolution Ultima Plus Wall Panels, featuring our standard CLEANsafe 15 coating in a flat profile finish.

Contact Kingspan to discuss additional coating options and project-specific requirements.

Insulation Core:

K-Roc® Evolution Ultima Plus Wall Panels are manufactured with a 115 kg/m³ density mineral wool insulation core with a tolerance of ± 10%

Coatings

External Weather Sheet:

  • Colours as per the Kingspan Australia colour range, please contact your local area sales manager for further information.

Internal Liner:

  • Kingspan CLEANsafe 15: The coating has been developed for use as the internal lining of insulated panels. Standard colour is “bright white” with an easily cleaned surface.

Other Internal Coating Options*

  • Kingspan AQUAsafe 25 and Kingspan AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments.

*Please contact Technical Services for further information regarding substrates and coatings.

Seals

Factory-applied side joint seals. External side joints have a factory-applied seal fitted into the groove to seal the joint between panels.

Downloads

Viewing 4 downloads
kingspan-k-roc-evolution-ultima-plus-wall-panel-data-sheet-en-au.pdf

K-Roc® Evolution Ultima Plus Wall Panel Data Sheet

Data Sheets
Download
kingspan-insulated-panels-colorbook-au-en.pdf

External Colour Range

Brochures
Download
kingspan-data-centre-digital-brochure-en-au.pdf

Data Centre Solutions

Brochures
Download
kingspan-kip-product-lookbook-au.pdf

Product Lookbook

Brochures
Download
Video Showcase

Canberra Library Repository

When a building is going to be housing rare books and irreplaceable artefacts, it is crucial that it can provide a safe environment – one that can protect its contents from both the risk of fire and the effects of extreme weather. The new extension of the National Library of Australia Repository in Canberra was designed to achieve just that, using Kingspan K-Roc™ Evolution Ultima Plus wall panels and Kingspan Roof Panels to create a robust and high-performing building envelope.

How can we help?

Our team can assist with product selection, technical guidance and specification advice for your next project.