Technical Information
For all technical information and specifications, please refer to the Product Data Sheet.
Applications
Kingspan K-PIR Wall Panels are a through-fix solution that can be used in both horizontal and vertical orientations.
Dimensions, Thermal Performance & Weight
| Total R-Value (m²K/W) | Total R-Value (m²K/W) | ||||||
|---|---|---|---|---|---|---|---|
| A - Core Thickness (mm) | B - Overall Thickness (mm) | Declared R-Value (m²K/W) at 23°C | Product R-Value (m²K/W) at 23°C | Product U-Value (W/m²K) at 23°C | Heat Flow Out (Winter) | Heat Flow In (Summer) | Weight (kg/m²)[ |
| 30 | 65 | 1.35 | 1.39 | 0.721 | 1.61 | 1.49 | 8.0 |
| 40 | 75 | 1.85 | 1.88 | 0.531 | 2.13 | 1.97 | 8.5 |
| 60 | 95 | 2.85 | 2.89 | 0.347 | 3.18 | 2.93 | 9.3 |
| 70 | 105 | 3.35 | 3.39 | 0.295 | 3.71 | 3.42 | 9.8 |
| 80 | 115 | 3.90 | 3.91 | 0.256 | 4.25 | 3.92 | 10.0 |
| 100 | 135 | 4.90 | 4.95 | 0.202 | 5.33 | 4.92 | 11.0 |
| 120 | 155 | 5.95 | 6.00 | 0.167 | 6.43 | 5.93 | 11.8 |
| 140 | 175 | 7.05 | 7.06 | 0.142 | 7.54 | 6.95 | 12.5 |
Declared Thermal Conductivity (λ Value) 0.023 W/mK @23°C (insulant thickness ≤ 40 mm).
Declared Thermal Conductivity (λ Value) 0.022 W/mK @23°C (insulant thickness 60 mm to 80 mm).
Declared Thermal Conductivity (λ Value) 0.021 W/mK @23°C (insulant thickness ≥100 mm).
Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code. The R-Values shown above are the total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2: 2018. K-PIR™ Roof Panels are manufactured, tested and packaged in conformance with AS/NZS 4859.1: 2018.
* Actual weight subject to vary ±10% due to manufacturing and raw material tolerances.
Certification & Testing
Reaction to Fire:
Ignitability Index: 0 as per AS/NZS: 1530.3: 1999
Spread of Flame Index: 0 as per AS/NZS: 1530.3: 1999
Heat Evolved Index: 0 as per AS/NZS: 1530.3: 1999
Smoke Developed Index: 3 as per AS/NZS: 1530.3: 1999
Group number:
When assessed in accordance with AS 5637.1:2015 via testing to AS ISO 9705:2003 (R2016) K-PIR Wall Panel achieves the following:
Group Number: 1
Smoke growth rate index (SMOGRARC) (m2/S2 x 1000): <100.
Insurer Approvals:
K-PIR Wall Panels are tested to:
FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials, unlimited height for thicknesses 40mm to 120mm.
FM 4881 approval standard for class 1 exterior wall systems, unlimited height for thicknesses 40mm to 120mm.
FM Approvals are subject to the following certified names:
For 1000mm widths: KS1000RW
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, half-yearly and yearly factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, width, orientation, method of assembly, steel coating and manufacturing facility.
Please contact our Technical team for project specific details.
Product Tolerance
The following dimensional tolerances apply to K-PIR Wall Panels.
| Dimension | Tolerance |
|---|---|
| Length < 3 m | ±5 mm |
| Length > 3 m | ±10 mm |
| Cover Width | ±2 mm |
| Thickness < 100 mm | ±2 mm |
| Thickness > 100 mm | ±2% |
| Squareness | ≤0.6% of width |
Acoustic Performance
For a sound transmission reduction, K-PIR Wall Panels have a weighted sound reduction index (SRI) of RW =24-26dB*. Results are based on panels with a of similar profile and core material.
*Please contact our Technical Team for project specific support and product specification where Rw = 26dB is required
| Frequency (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Rw |
|---|---|---|---|---|---|---|---|---|---|
| SRI (dB) | 20 | 18 | 20 | 24 | 20 | 29 | 39 | 46 | 24 |
Environmental
Kingspan Insulated Panels manufacturing facility in Australia procures steel that is made from 15-25% recycled content.
K-PIR Wall Panels have Environmental Product Declarations in accordance with the requirements of ISO 14025 and EN 15804: 2012 + A2: 2019 for 40mm to 120mm thickness.
K-PIR Wall Panels are certified with a Global GreenTag GreenRate™ Level A certification to Version 4.1 of the Global GreenTag International Product Certification Standard, under the certified name Kingspan Wall Panels. A GreenRate Level A license is the highest-ranking level in GreenTag’s GreenRate program. As a result, K-PIR Wall Panels receive the maximum recognition by the Green Building Council of Australia’s Green Star® building rating tools scheme. The recognition provides assurance to green building projects that the product has demonstrated a maximum commitment to low toxicity, compliance to relevant social and environmental laws in the country of operation, fit for purpose certification, availability of replacement parts, a design for recycling and/or reuse and healthy VOC levels.
Materials & Coatings
External Weather Sheet
Materials: G300S steel with AM100 or AM150 metallic coating in accordance with AS 1397:2021
Coating: Paint Coating in accordance with AS / NZS 2728:2013. Colours as per the Kingspan Australia color range, please contact your local area sales manager for further information.
Internal Liner
Materials: G300S steel with AM100 metallic coating in accordance with AS 1397:2021
Coating: Paint Coating in accordance with AS / NZS 2728:2013. Kingspan CLEANsafe 15: The coating has been developed for use as the internal lining of insulated panels. Standard colour is “bright white” with an easily cleaned surface
* Other coating options:
- Kingspan AQUAsafe: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments
- Kingspan AQUAsafe 25 and AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to swimming pool internal environments
(*) Please contact our Technical Team for further information regarding substrates and coatings. Internal coatings subject to availability and panel cover width.
Insulation Core
Polyisocyanurate core (PIR)
Seals
All panel joints have a factory applied weather seal fitted on the underside of the sidelap to automatically seal the joint between panels.
Panel End Cut Back
Min. Cut Back: 50 mm
End Lap Horizontally or Vertically Laid: 75 mm
End Lap Horizontally or Vertically Laid: 100 mm
Max. Cut Back: 200 mm
*For cutbacks larger than 200 mm, the core material and the steel at the cut back will not be removed and will have to be carried out on site by the installer.
Downloads
View K-PIR™ Wall Panel Technical Documents