Technical Info
For all technical information and specifications, please refer to the Product Data Sheet.
Applications
K-PIR™ Karrier Wall Panels are factory-engineered panel systems that provide the structural support, thermal and weather protection for direct-fix or ventilated cavity rainscreen facades. Panels can be used for both vertical or horizontal orientations.
Dimensions, Thermal Performance & Weight
| Total R-Value (m²K/W) | Total R-Value (m²K/W) | |||||
|---|---|---|---|---|---|---|
| Panel Nominal Thickness (mm) | Declared R-Value (m²K/W) at 23°C | Product R-Value (m²K/W) at 23°C | Product U-Value (m²K/W) at 23°C | Heat Flow Out (Winter) | Heat Flow In (Summer) | Weight* (kg/m²) |
| 50 | 2.20 | 2.21 | 0.453 | 2.47 | 2.28 | 10.8 |
| 75 | 3.45 | 3.46 | 0.290 | 3.77 | 3.48 | 11.8 |
| 100 | 4.70 | 4.74 | 0.212 | 5.11 | 4.71 | 12.8 |
| 125 | 6.00 | 6.04 | 0.166 | 6.47 | 5.97 | 13.8 |
| 150 | 7.35 | 7.37 | 0.136 | 7.86 | 7.25 | 14.8 |
| 200 | 10.05 | 10.08 | 0.100 | 10.69 | 9.85 | 16.8 |
Declared Thermal Conductivity (λ Value) 0.023 W/mK @23°C (thickness ≤ 50mm)
Declared Thermal Conductivity (λ Value) 0.022 W/mK @23°C (thickness 75mm)
Declared Thermal Conductivity (λ Value) 0.021 W/mK @23°C (thickness 100-150mm)
Declared Thermal Conductivity (λ Value) 0.020 W/mK @23°C (thickness 200mm)
Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code.
The R-Values shown above are the total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/ NZS 4859.2: 2018. K-PIR Karrier Wall Panels are manufactured, tested and packaged in conformance with AS/NZS 4859.1: 2018.
* Actual weight subject to vary ±10% due to manufacturing and raw material tolerances.
Certification & Testing
Reaction to Fire:
Ignitability Index: 0 as per AS/NZS: 1530.3: 1999
Spread of Flame Index: 0 as per AS/NZS: 1530.3: 1999
Heat Evolved Index: 0 as per AS/NZS: 1530.3: 1999
Smoke Developed Index: 1 as per AS/NZS: 1530.3: 1999
NCC Group Number in accordance with AS 5637.1: 2015 : Group 2
Smoke Growth Rate Index (SMOGRARC) (m²/S² x 1000) in accordance with AS 5637.1: 2015/ISO 9705 2003 : <100
Acoustic Performance
For sound transmission reduction, KS1100KP Karrier Wall Panels have a weighted sound reduction index (SRI) of RW =24dB. Results are based on panels with a of similar profile and core material.
For specific acoustic information, contact Technical Team.
| Frequency (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Rw |
|---|---|---|---|---|---|---|---|---|---|
| SRI (dB) | 20 | 18 | 20 | 24 | 20 | 29 | 39 | 46 | 24 |
Environmental
Kingspan Insulated Panels manufacturing facility in Australia procures steel that is made from 15-25% recycled content
K-PIR Karrier Wall Panels have Environmental Product Declarations in accordance with the requirements of ISO 14025 and EN 15804: 2012 + A2: 2019 for 50mm to 200mm thickness
K-PIR Karrier Wall Panels are certified with a Global GreenTag GreenRate™ Level A certification to Version 4.1 of the Global GreenTag International Product Certification Standard, under the certified name Kingspan Wall Panels. A GreenRate Level A license is the highest-ranking level in GreenTag’s GreenRate program. As a result, K-PIR Karrier Wall Panels receive the maximum recognition by the Green Building Council of Australia’s Green Star® building rating tools scheme. The recognition provides assurance to green building projects that the product has demonstrated a maximum commitment to low toxicity, compliance to relevant social and environmental laws in the country of operation, fit for purpose certification, availability of replacement parts, a design for recycling and/or reuse and healthy VOC levels
Product Tolerance
| Description | Tolerance |
|---|---|
| Length < 3 m | ±5 mm |
| Length > 3 m | ±10 mm |
| Cover Width | ±2 mm |
| Thickness (≤100 mm) | ±2 mm |
| Thickness (>100 mm) | ± 2% |
| Squareness | ≤0.6% of width |
| Flatness* | |
| L = 200 mm | 0.6 mm |
| L = 400 mm | 1.0 mm |
| L > 700 | 1.5 mm |
| Bowing | 2 mm per metre length upto max 20 mm |
*Flatness shall be measured at least 100mm from the edge of panel and 200mm from the end of panel.
Materials & Coatings
Materials:
External Weather Sheet
G300S steel with AM100 or AM150 metallic coating in accordance with AS 1397: 2021.
Paint Coating in accordance with AS / NZS 2728: 2013.
Internal Liner
G300S with Z275 metallic coating in accordance with AS 1397.1:2021
Paint coating in acccordance with AS/NZS 2728:2013
Coatings:
External Weather Sheet
Standard: Windspray
Internal Liner
Colour: Off White
*Other Internal Coating Options
Kingspan AQUAsafe: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments
Kingspan AQUAsafe 25 and Kingspan AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to swimming pool internal environments
*Please contact our Technical team for further information regarding substrates and coatings. Internal coatings subject to availability and panel cover width.
Insulation Core:
Manufactured with a polyisocyanurate (PIR) core.
Quality & Durability
K-PIR Karrier Wall Panels are manufactured from high quality materials, using state-of-the-art production equipment to rigorous quality control standards, complying with ISO 9001 standard, ensuring long-term reliability and service life. The panels are also being manufactured under Environmental Management System Certification ISO 14001 and Occupational Health and Safety Certification ISO 45001.
Downloads
View K-PIR™ Karrier Technical Documents