Technical Information
For all technical information and specifications, please refer to the Product Data Sheet.
Dimensions, Thermal Performance & Weight
| Total R-Value (m²K/W) | Total R-Value (m²K/W) | Weight* (kg/m2 | Total R-Value (m²K/W) | ||||
|---|---|---|---|---|---|---|---|
| Panel Nominal Thickness (mm) | Declared R-Value (m²K/W) at 23°C | Product R-Value (m²K/W) at 23°C | Product U-Value (W/m²K) at 23°C | Heat Flow Out (Winter) | Heat Flow In (Summer) | 1,100 mm cover width | 1,200 mm cover width |
| 50 | 2.20 | 2.21 | 0.452 | 2.46 | 2.32 | 11.3 | 11.5 |
| 75 | 3.45 | 3.46 | 0.289 | 3.76 | 3.52 | 12.0 | 12.5 |
| 80 | 3.70 | 3.71 | 0.270 | 4.03 | 3.77 | 12.3 | 12.8 |
| 100 | 4.70 | 4.74 | 0.211 | 5.10 | 4.75 | 13.0 | 13.5 |
| 125 | 6.00 | 6.04 | 0.166 | 6.46 | 6.01 | 14.0 | 14.5 |
| 150 | 7.35 | 7.37 | 0.136 | 7.85 | 7.29 | 15.0 | 15.5 |
| 200 | 10.05 | 10.08 | 0.099 | 10.68 | 9.89 | 17.0 | 17.5 |
Declared Thermal Conductivity (λ Value) 0.023 W/mK @23°C (thickness ≤ 50 mm).
Declared Thermal Conductivity (λ Value) 0.022 W/mK @23°C (thickness 75 mm to 80 mm).
Declared Thermal Conductivity (λ Value) 0.021 W/mK @23°C (thickness 100 mm to 150 mm).
Declared Thermal Conductivity (λ Value) 0.020 W/mK @23°C (thickness 200 mm).
Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code. The R-Values shown above are the total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2: 2018.
K-PIR™ Roofliner Panels are manufactured, tested and packaged in conformance with AS/NZS 4859.1: 2018.
* Actual weight subject to vary ±10% due to manufacturing and raw material tolerances.
Applications
K-PIR™ Roofliner Panel is to be used as an insulated composite panel installed under site applied, fully supported or self-supported aluminium, copper, zinc, as well as pre-painted and stainless steel roof systems.
Insulation Core
K-PIR™ Roofliner Panels are manufactured with a polyisocyanurate (PIR) core.
Certification and Testing
Reaction to Fire:
Ignitability Index: 0 as per AS/NZS: 1530.3: 1999
Spread of Flame Index: 0 as per AS/NZS: 1530.3: 1999
Heat Evolved Index: 0 as per AS/NZS: 1530.3: 1999
Smoke Developed Index: 2 as per AS/NZS: 1530.3: 1999
Group number:
When assessed in accordance with AS 5637.1:2015 via testing to AS ISO 9705:2003 (R2016) K-PIR Roofline Panel achieves the following:
Group 1: 1,200 mm
Group 2: 1,100 mm
Smoke growth rate index (SMOGRARC) (m2/S2 x 1000): <100.
Acoustic Performance
For specific acoustic information, contact our Technical Team.
| Frequency (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Rw |
|---|---|---|---|---|---|---|---|---|---|
| SRI (dB) | 20 | 18 | 20 | 24 | 20 | 29 | 39 | 46 | 24 |
Environmental
Kingspan Insulated Panels manufacturing facility in Australia procures steel that is made from 15-25% recycled content.
K-PIR Roofliner Panels have Environmental Product Declarations in accordance with the requirements of ISO 14025 and EN 15804: 2012 + A2: 2019 for 50mm to 200mm thickness.
K-PIR Roofliner Panels are certified with a Global GreenTag GreenRate™ Level A certification to Version 4.1 of the Global GreenTag International Product Certification Standard, under the certified name Kingspan Roof Panels. A GreenRate Level A license is the highest-ranking level in GreenTag’s GreenRate program. As a result, K-PIR Roofliner Panels receive the maximum recognition by the Green Building Council of Australia’s Green Star® building rating tools scheme. The recognition provides assurance to green building projects that the product has demonstrated a maximum commitment to low toxicity, compliance to relevant social and environmental laws in the country of operation, fit for purpose certification, availability of replacement parts, a design for recycling and/or reuse and healthy VOC levels.
Product Tolerance
Length < 3 m | ±5 mm |
Length > 3 m | ±10 mm |
Cover Width | ±2 mm |
Thickness (≤100 mm) | ±2 mm |
Thickness (>100 mm) | ± 2% |
Squareness | ≤0.6% of width |
Flatness* | |
L = 200 mm | 0.6 mm |
L = 400 mm | 1.0 mm |
L > 700 | 1.5 mm |
Bowing | 2 mm per metre length up to max 20 mm |
(*) : Flatness shall be measured at least 100mm from the edge of panel and 200mm from the end of panel.
Materials & Coatings
Substrate Material:
G300S steel with Z275 metallic coating in accordance with AS 1397:2021
Paint Coating in accordance with AS/NZS 2728:2013
Coatings:
Standard: Off-White
Other colours are available on request. Please contact your local area sales manager for further information
*Other Internal Coatings Options:
Kingspan AQUAsafe: The coating has been developed for use as the internal lining of insulated panels to suit environments that require long term corrosion resistance and durability, facilities such as washrooms / fabric manufacturing, agricultural and livestock facilities
Kingspan AQUAsafe 25 and Kingspan AQUAsafe 55: The coating has been developed for use as the internal lining of insulated panels to swimming pool internal environments
(*) Please contact our Techincal team for further information regarding substrates and coatings. Internal coatings subject to availability and panel cover width.
Panel Joint
The tongue and groove joint achieves excellent thermal performance. The panel side joint can accommodate vapour or hygiene safe seals.
Quality and Durability
K-PIR™ Roofliner Panels are manufactured from the high quality materials using state-of-the-art production equipment to rigorous quality control standards, complying with ISO 9001 standard, ensuring long-term reliability and service life. The panels are also being manufactured under Environmental Management System Certification ISO 14001 and Occupational Health and Safety Certification ISO 45001.